ASTM E989撞擊緩沖等級(IIC)測定的標(biāo)準(zhǔn)分類
ASTM E989  Standard Classification for Determination of Impact Insulation Class (IIC)
ASTM E989撞擊緩沖等級(IIC)測定的標(biāo)準(zhǔn)分類

The rating increases as the impact sound attenuation of the floor ceiling structure increases. The rating can be used by architects, builders, and specification and code authorities for acoustical design purposes in building constructions.
4.2 The rating strictly only applies to excitation by the standard tapping machine defined in Test Methods E 492 and E 1007. It does not deal with low frequency sounds below 100 Hz that are typically generated below lightweight joist floors when they are walked on. Nor does it deal with the squeaking, crunching or rattling sounds that can occur in joist construction when elements in the construction are loose and occupants walk on the floor.
4.3 This classification shall only be used with one-third octave band data.
1. Scope
1.1 This classification provides a method for determining a rating that can be used to compare the levels of impact noise generated by a standard tapping machine and transmitted through different floor-ceiling assemblies.
1.2 The name given to the rating is assigned by the test method that invokes this classification.
1.3 This classification is applicable only to one third octave band impact noise data obtained using the standard tapping machine described in Test Methods E 492 and E 1007.
1.4 Test methods that invoke this classification include:
1.4.1 Test Method E 492 - the single-number rating is called impact insulation class (IIC).
1.4.2 Test Method E 1007 - the single-number rating is called field impact insulation class (FIIC).
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
C634 Terminology Relating to Building and Environmental Acoustics
E492 Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping Machine
E1007 Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures
Index Terms
floors; IIC; impact noise; impact rating; tapping machine;

  詳情請咨詢
  防火資源網(wǎng)-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網(wǎng)"的所有作品,由<防火資源網(wǎng)>整理編輯,任何組織未經(jīng)<防火資源網(wǎng)>及其擁有者授權(quán),不得復(fù)制、轉(zhuǎn)載、摘編或利用其它方式應(yīng)用于任何商業(yè)行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關(guān)閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點(diǎn)擊排行
 
 
網(wǎng)站首頁 | 廣告服務(wù) | 關(guān)于我們 | 聯(lián)系方式 | 服務(wù)協(xié)議 | 版權(quán)聲明 | 網(wǎng)站地圖 | 友情鏈接 | 網(wǎng)站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:在線客服 點(diǎn)擊QQ交談/留言 點(diǎn)擊QQ交談/留言