压在透明的玻璃上c_又色又爽又黄又免费的视频软件_av无码专区亚洲av波多野结衣_国产在线每日都有更新 - www国产视频

阻燃防火材料-網上貿易平臺 | | WAP瀏覽
服務熱線:4006555305
當前位置: 首頁 » 防火測試中心 » 各國標準法規 » 美國 » 正文

ASTM E989撞擊緩沖等級(IIC)測定的標準分類

放大字體  縮小字體 發布日期:2012-02-08   瀏覽次數:478  分享到: 分享到騰訊微博
ASTM E989撞擊緩沖等級(IIC)測定的標準分類
ASTM E989  Standard Classification for Determination of Impact Insulation Class (IIC)
ASTM E989撞擊緩沖等級(IIC)測定的標準分類

The rating increases as the impact sound attenuation of the floor ceiling structure increases. The rating can be used by architects, builders, and specification and code authorities for acoustical design purposes in building constructions.
4.2 The rating strictly only applies to excitation by the standard tapping machine defined in Test Methods E 492 and E 1007. It does not deal with low frequency sounds below 100 Hz that are typically generated below lightweight joist floors when they are walked on. Nor does it deal with the squeaking, crunching or rattling sounds that can occur in joist construction when elements in the construction are loose and occupants walk on the floor.
4.3 This classification shall only be used with one-third octave band data.
1. Scope
1.1 This classification provides a method for determining a rating that can be used to compare the levels of impact noise generated by a standard tapping machine and transmitted through different floor-ceiling assemblies.
1.2 The name given to the rating is assigned by the test method that invokes this classification.
1.3 This classification is applicable only to one third octave band impact noise data obtained using the standard tapping machine described in Test Methods E 492 and E 1007.
1.4 Test methods that invoke this classification include:
1.4.1 Test Method E 492 - the single-number rating is called impact insulation class (IIC).
1.4.2 Test Method E 1007 - the single-number rating is called field impact insulation class (FIIC).
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
C634 Terminology Relating to Building and Environmental Acoustics
E492 Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping Machine
E1007 Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures
Index Terms
floors; IIC; impact noise; impact rating; tapping machine;

  詳情請咨詢
  防火資源網-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網"的所有作品,由<防火資源網>整理編輯,任何組織未經<防火資源網>及其擁有者授權,不得復制、轉載、摘編或利用其它方式應用于任何商業行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網站首頁 | 廣告服務 | 關于我們 | 聯系方式 | 服務協議 | 版權聲明 | 網站地圖 | 友情鏈接 | 網站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:在線客服 點擊QQ交談/留言 點擊QQ交談/留言