ASTM C1015 纖維素和礦物纖維松充填熱絕緣料裝配的標準規范

放大字體  縮小字體 發布日期:2012-02-08   瀏覽次數:55  分享到: 分享到騰訊微博
ASTM C1015 纖維素和礦物纖維松充填熱絕緣料裝配的標準規范
ASTM C1015 Standard Practice for Installation of Cellulosic and Mineral Fiber Loose-Fill Thermal Insulation
ASTM C1015 纖維素和礦物纖維松充填熱絕緣料裝配的標準規范
This practice recognizes that effectiveness, safety, and durability of insulation depend not only on the quality of the insulating materials, but also on their proper installation.
Improper installation of insulation can reduce its thermal effectiveness, cause fire risks and other unsafe conditions, and promote deterioration for the structure in which it is installed. Specific hazards that can result from improper installation include fires caused by (1) heat build-up in recessed lighting fixtures; (2) deterioration or failure of electrical wiring components; (3) heat build-up resulting from overcurrent protection devices incorrectly matched to wiring; or (4) deterioration in wood structures and paint failure due to moisture accumulation.
This practice provides general procedures that will help ensure the installation of insulation in a safe and effective manner. It must be noted that actual conditions in existing buildings vary greatly, and in some cases substantial additional care and precaution must be taken to ensure effective and safe installation.
1. Scope
1.1 This practice covers procedures for the installation of cellulosic and mineral fiber loose-fill insulation in ceilings, attics, and floor and wall cavities of new or existing housing and other framed buildings.
1.2 This practice applies only to the installation of dry loose-fill thermal insulation consisting of cellulosic materials or mineral fiber by pneumatic or pouring application.
1.3 This practice covers the installation process from pre-installation inspection through post-installation procedure. It does not cover the production of the insulation materials.
1.4 This practice is not intended to replace the manufacturer's installation instructions, but shall be used in conjunction with such instructions. This practice is not intended to supersede local, state, or federal codes.
1.5 This practice assumes that the installer possesses a good working knowledge of the applicable codes and regulations, safety practices, tools, equipment, and methods necessary for the installation of thermal insulation materials. It also assumes that the installer understands the fundamentals of residential construction that affect the installation of insulation.
1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section .

2. Referenced Documents (purchase separately)
ASTM Standards
C168 Terminology Relating to Thermal Insulation
C739 Specification for Cellulosic Fiber Loose-Fill Thermal Insulation
C755 Practice for Selection of Water Vapor Retarders for Thermal Insulation
C764 Specification for Mineral Fiber Loose-Fill Thermal Insulation
NFPA Standards
ICC Document
Federal Standard
Index Terms
cellulose; installation; light frame construction; loose fill; mineral fiber;

  詳情請咨詢
  防火資源網-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網"的所有作品,由<防火資源網>整理編輯,任何組織未經<防火資源網>及其擁有者授權,不得復制、轉載、摘編或利用其它方式應用于任何商業行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網站首頁 | 廣告服務 | 關于我們 | 聯系方式 | 服務協議 | 版權聲明 | 網站地圖 | 友情鏈接 | 網站留言 | 舊版本 | 閩ICP備09009213號
?2012-2014 FIRETC.COM All Rights Reserved ? 在線客服 點擊QQ交談/留言 點擊QQ交談/留言