ASTM F1695下烤式烘烤爐性能的標準試驗方法

放大字體  縮小字體 發布日期:2012-02-08   瀏覽次數:45  分享到: 分享到騰訊微博
ASTM F1695下烤式烘烤爐性能的標準試驗方法
ASTM F1695 Standard Test Method for Performance of Underfired Broilers
ASTM F1695下烤式烘烤爐性能的標準試驗方法

The energy input rate test is used to confirm that the underfired broiler is operating properly prior to further testing.
Temperature distribution of the broiling area may be used by food service operators to select an underfired broiler with the desired temperature gradients.
Preheat energy and time can be useful to food service operators to manage energy demands and to know how quickly the underfired broiler can be ready for operation.
Cooking energy efficiency is a precise indicator of underfired broiler energy performance under various loading conditions. This information enables the food service operator to consider energy performance when selecting an underfired broiler.
Production capacity allows the food service operator to select an underfired broiler that meets their food output requirements.
1. Scope
1.1 This test method covers the evaluation of the energy consumption and cooking performance of underfired broilers. The food service operator can use this evaluation to select an underfired broiler and understand its energy performance.
1.2 This test method is applicable to gas and electric underfired broilers.
1.3 The underfired broiler can be evaluated with respect to the following (where applicable):
1.3.1 Energy input rate (see 10.2),
1.3.2 Temperature distribution across the broiling area (see 10.3),
1.3.3 Preheat energy and time (see 10.4),
1.3.4 Pilot energy rate, if applicable (see 10.5),
1.3.5 Cooking energy rate (see 10.6), and
1.3.6 Cooking energy efficiency and production capacity (see 10.7).
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
A36/A36M Specification for Carbon Structural Steel
D3588 Practice for Calculating Heat Value, Compressibility Factor, and Relative Density of Gaseous Fuels
ANSI Standard
ANSIZ83.11 American National Standard for Gas Food Service Equipment
AOAC Documents
AOACOfficialAction96 Fat (Crude) or Ether Extract in Meat
ASHRAE Document
ASHRAEGuideline2-198 (RA90) Engineering Analysis of Experimental Data
Other Document
DevelopmentandValida
Index Terms
cook time; energy efficiency; performance; test method; underfired broiler; Cooking energy efficiency (CEE); Cooking/food service equipment; Cooking/food service equipment performance; Energy efficiency; Underfired broilers;

  詳情請咨詢
  防火資源網-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網"的所有作品,由<防火資源網>整理編輯,任何組織未經<防火資源網>及其擁有者授權,不得復制、轉載、摘編或利用其它方式應用于任何商業行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網站首頁 | 廣告服務 | 關于我們 | 聯系方式 | 服務協議 | 版權聲明 | 網站地圖 | 友情鏈接 | 網站留言 | 舊版本 | 閩ICP備09009213號
?2012-2014 FIRETC.COM All Rights Reserved ? 在線客服 點擊QQ交談/留言 點擊QQ交談/留言