NFPA 13E 在自動噴水和立管系統(tǒng)保護(hù)地區(qū)消防隊(duì)員滅火推薦做法

放大字體  縮小字體 發(fā)布日期:2012-02-08   瀏覽次數(shù):171  分享到: 分享到騰訊微博
NFPA 13E 在自動噴水和立管系統(tǒng)保護(hù)地區(qū)消防隊(duì)員滅火推薦做法

NFPA 13E Recommended Practice for Fire Department Operations in Properties Protected by Sprinkler and Standpipe Systems
NFPA 13E 在自動噴水和立管系統(tǒng)保護(hù)地區(qū)消防隊(duì)員滅火推薦做法

 

This recommended practice provides basic procedures and information for use in fire department operations concerning properties equipped with certain fixed fire protection systems. The fixed systems covered in this recommended practice are interior automatic sprinkler systems, exterior sprinkler systems, and standpipe systems.

 

 

NFPA 13E assists fire service response in buildings protected by sprinkler systems.

The updated 2010 edition of NFPA 13E Recommended Practice for Fire Department Operations in Properties Protected by Sprinkler and Standpipe Systems provides critical information and procedures for fire department operations in properties equipped with fire sprinkler and standpipe systems. This important recommended practice addresses

·   Interior automatic sprinkler systems

·   Exterior sprinkler systems

·   Standpipe systems

Added visuals help fire service personnel visualize concepts.

The 2010 NFPA 13E includes additional illustrations of primary sprinkler/standpipe system valves and an improved illustration of a typical sprinkler system layout, using symbols from the 2009 NFPA 170 Standard for Fire Safety and Emergency Symbols. This edition also clarifies the use of alternative water supplies for fire department support of sprinkler and standpipe systems. Annex B contains recommendations for Fighting Rubber Tire Fires in Sprinklered Buildings.

Fire department officers, fire fighters, company officers, fire department instructors will benefit from procedures designed to assist in developing training programs and planning effective operations. Recommended practices are given for the adequate support and use of sprinkler and standpipe systems. (Softbound, 14 pp., 2010)


  詳情請咨詢
  防火資源網(wǎng)-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網(wǎng)"的所有作品,由<防火資源網(wǎng)>整理編輯,任何組織未經(jīng)<防火資源網(wǎng)>及其擁有者授權(quán),不得復(fù)制、轉(zhuǎn)載、摘編或利用其它方式應(yīng)用于任何商業(yè)行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關(guān)閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點(diǎn)擊排行
 
 
網(wǎng)站首頁 | 廣告服務(wù) | 關(guān)于我們 | 聯(lián)系方式 | 服務(wù)協(xié)議 | 版權(quán)聲明 | 網(wǎng)站地圖 | 友情鏈接 | 網(wǎng)站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:閩ICP備09009213號-1在線客服 點(diǎn)擊QQ交談/留言 點(diǎn)擊QQ交談/留言