1.1 Scope.
1.1.1 This standard applies to purging and pressurizing for the following
(1) Electrical equipment located in areas classified as hazardous by Article 500 or Article 505 of NFPA 70
(2) Electrical equipment containing sources of flammable vapors or gases and located in either classified or unclassified areas
(3) Control rooms or buildings located in areas classified as hazardous by Article 500 or Article 505 of NFPA 70
(4) Analyzer rooms containing sources of flammable vapors or gases and located in areas classified as hazardous by Article 500 or Article 505 of NFPA 70
1.1.2* This standard does not apply to electrical equipment located in
(1) Areas classified as Class I, Zone 0
(2) Areas classified as Class III
(3) Areas where flammable liquids may be splashed or spilled on the electrical equipment.
 
 
Protect electrical equipment in flammable atmospheres by following the protection techniques outlined in the 2008 NFPA 496.
NFPA 496 Purged and Pressurized Enclosures for Electrical Equipment contains requirements for the design and operation of purged and pressurized electrical equipment enclosures. This protection technique is used in Class I and Class II hazardous (classified) locations to reduce or prevent the presence of flammable materials within electrical equipment enclosures as specified by NFPA 70® National Electrical Code®. NFPA 496 also includes chapters covering protection of analyzers and rooms housing analyzers as well as a chapter on pressurized control rooms.
Consistent with the 2008 NEC®, the 2008 NFPA 496 includes the following updates to help control fire hazards
·   A new requirement to mark purged and pressurized enclosures with an asphyxiation hazard warning where the protective gas is other than air
·   Correlation with the NEC requirements on equipment temperature ratings
(Softbound, 22 pp., 2008)

  詳情請咨詢
  防火資源網(wǎng)-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網(wǎng)"的所有作品,由<防火資源網(wǎng)>整理編輯,任何組織未經(jīng)<防火資源網(wǎng)>及其擁有者授權(quán),不得復(fù)制、轉(zhuǎn)載、摘編或利用其它方式應(yīng)用于任何商業(yè)行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關(guān)閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網(wǎng)站首頁 | 廣告服務(wù) | 關(guān)于我們 | 聯(lián)系方式 | 服務(wù)協(xié)議 | 版權(quán)聲明 | 網(wǎng)站地圖 | 友情鏈接 | 網(wǎng)站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:閩ICP備09009213號-1在線客服 點擊QQ交談/留言 點擊QQ交談/留言