ASTM D2220 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 75°C Operation
ASTM D2220工作溫度75℃時電線和電纜的聚氯乙烯絕緣性的標準規范
This specification covers a thermoplastic poly(vinyl chloride) insulation for wire and cable at the prescribed temperature. This insulation is recommended for use in power and control circuits at the specified thickness and voltage ratings and to dry locations. Tests are done on insulated wire or cable in this specification solely to determine the relevant property of the insulation material and not to test the conductor or completed cable. The insulation shall conform to the physical property requirements prescribed for the following: (1) tensile strength and elongation for unaged specimen and aged (using air oven test) tubular and buffed die-cut specimen, (2) heat shock, (3) heat distortion, (4) vertical flame test, (5) tensile strength and elongation for oil resistance test, and (6) cold bond test. Electrical tests shall be performed in the following order: ac voltage test, insulation resistance test, and dc voltage test. The insulation shall conform to the other electrical requirements such as accelerated water absorption (including permittivity and capacitance) and dielectric strength, and shall meet the prescribed thickness as well.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 This specification covers a thermoplastic insulation of poly(vinyl chloride) or the copolymer of vinyl chloride and vinyl acetate.
1.2 This insulation is recommended for use in power and control circuits at temperatures not higher than 75°C. At a thickness of 15 mils (0.38 mm), application is limited to voltage ratings below 300 V, and to dry locations. At a thickness of 30 mils, the application range is widened to dry or wet applications, and to a voltage rating of 600 V.
1.3 In many instances the insulation material cannot be tested unless it has been formed around a conductor or cable. Therefore, tests are done on insulated wire or cable in this specification solely to determine the relevant property of the insulation material and not to test the conductor or completed cable.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4.1 In come cases (including the title), temperatures are described in degrees Celsius only.
2. Referenced Documents (purchase separately)
ASTM Standards
D1711 Terminology Relating to Electrical Insulation
D2633 Test Methods for Thermoplastic Insulations and Jackets for Wire and Cable
D2633 Test Methods for Thermoplastic Insulations and Jackets for Wire and Cable
Index Terms
accelerated water absorption; ac voltage test; dc voltage test; insulation resistance; poly (vinyl chloride) insulation; 75 C Poly (Vinyl Chloride) Insulation; thickness;