This practice covers procedures for obtaining data on the quality of solid electrical insulating materials and for judging whether the materials meet the requirements specified. This practice, however, is not intended to define internal quality control procedures of the producer; rather, it is designed to determine the acceptability of all, or some portion, of a quantity of electrical insulating materials available for inspection by the user of the material. In addition, this practice is intended for use in conjunction with existing material specifications including property characteristic limits, acceptable quality level, standard test methods, and sampling instructions. Data shall be obtained by taking lot samples randomly. Sampling plans are available in single, double, and multiple types. Acceptable quality levels for each critical, major, and minor property as well as inspection levels shall conform to the requirements specified. Acceptance of lot quality shall be determined based on the comparison of test results and other information obtained using the sampling plans with the requirements set forth in the material specification (nonconformity) and on whether the lot meets the requirements specified.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 This practice covers procedures for obtaining data pertaining to the quality of a lot of electrical insulating material and for making a judgement whether the lot meets the requirements of a material specification.
1.2 This practice is not intended to define a producer's internal quality control procedures but is designed to determine the acceptability of all, or some portion, of a quantity of electrical insulating material that is available for inspection by the user of the material.
1.3 This practice is intended to be used in conjunction with an existing material specification that specifies property characteristic limits, acceptable quality level (AQL), standard test methods, and specific sampling instructions.
1.4 In the absence of a specification as described in 1.3, use this practice as a guide, after establishment of agreed-upon property characteristics, limits, AQL, standard test methods, and specific sampling instructions.
1.5 It is intended that this be a practice for inspection by attributes.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately
ASTM Standards
E300 Practice for Sampling Industrial Chemicals
Military Standard
MIL-STD-105D Sampling Procedures and Tables for Inspection by Attributes
Other Document
ANSI/ASQCA2 -1987
Index Terms
acceptable quality level (AQL); critical property; electrical insulation; inspection; major property; minor property; nonconformity; nonconforming; quality judgment; sampling; test measurement; test result; Electrical insulating solids; Quality control (QC)--insulation (electrical); Sampling electrical inisulating materials;