ASTM E595-15 Outgassing 除氣測試/滲氣測試
ASTM E595-15 真空環境中放氣引起的總質量損失及收集的揮發性可凝結物的測試
ASTM E595-15 真空環境中放氣引起的總質量損失及收集的揮發性可凝結物的測試
關鍵字:ASTM E 595,ASTM E595,outgassing test,滲氣測試,除氣測試
ASTM E595-15 Outgassing 除氣測試/滲氣測試
ASTM E595 真空環境下除氣作用引起的總質量損失和揮發物質冷凝量的測試
ASTM E595 Standard Test Method for Total Mass Loss and Collected Volatile Condensable Materials from Outgassing in a Vacuum Environment
This test method covers a screening technique to determine volatile content of materials when exposed to a vacuum environment. Two parameters are measured: total mass loss (TML) and collected volatile condensable materials (CVCM).An additional parameter, the mount of water vapor regained (WVR), can also be obtained after completion of exposures and measurements required for TML and CVCM.
ASTM E595-15 Outgassing 除氣測試/滲氣測試-測試范圍
各種各樣的有機分子,聚合物和無機材料都可被測試。包括:聚合混合物,發泡材料,彈性體,薄膜,膠帶,絕緣體,收縮管,膠水,涂料,紡織面料,和輪滑油等等。
ASTM E595-15 Outgassing 除氣測試/滲氣測試-標準要求
CVCM (collected volatile condensable materials)揮發物質冷凝量, 要求≤0.1%
TML (total mass loss)總質量虧損,要求≤1%
WVR (the amount of water vapor regained)水汽量
備注:測試是否通過取決于TML和CVCM是否符合以上標準要求。
TML 1.00%和CVCM 0.10%的要求已經被作為航空材料篩選級。
ASTM E595-15 Outgassing 除氣測試/滲氣測試-測試環境
預處理環境:73F/50%(24小時) 后置環境:73F/50%(24小時)
測試參數:在257±2F(125°C)溫度,真空度單位≤5 x 10-5壓強情況下24小時除氣
預處理環境:73F/50%(24小時) 后置環境:73F/50%(24小時)
測試參數:在257±2F(125°C)溫度,真空度單位≤5 x 10-5壓強情況下24小時除氣