ISO 11925-2: 防火測試-直接對火建筑材料的點燃測試-第2部分:單個火源測試
ISO 11925-2: Reaction to fire tests -- Ignitability of building products subjected to direct impingement of flame -- Part 2: Single-flame source test
Abstract摘要
Classification according to Euro class B, Bfl, C, Cfl, D, Dfl, E and Efl according to the European System. Additional test methods are also used, see data sheet EN ISO 9239-1 and EN ISO 13823.
The test method measures the ignitability of building products when exposed to a small flame.
Examples of products that can be tested with this method
All types of building products, for example those comprised by fire regulations and included in the European Construction Product Directive, CPD.
Material consumption during test
Complete test, |
18 test specimens, 9 specimens in one direction (e.g. production direction) and 9 specimens in perpendicular direction to the first direction, with the dimension |
Indicative test, |
4 test specimens, 2 specimens in one direction (e.g. production direction) and 2 specimens in perpendicular direction to the first direction, with the dimension |