ASTM E1513噴涂耐火材料應(yīng)用(SFRMs)

放大字體  縮小字體 發(fā)布日期:2012-02-08   瀏覽次數(shù):199  分享到: 分享到騰訊微博
ASTM E1513噴涂耐火材料應(yīng)用(SFRMs)
ASTM E1513  Standard Practice for Application of Sprayed Fire-Resistive Materials (SFRMs)
ASTM E1513噴涂耐火材料應(yīng)用(SFRMs)
This practice is intended for use by the material specifier, general contractor, applicator, or any individual group requiring information regarding the application of SFRM.
This practice is not intended to replace the manufacturers' application instructions.
1. Scope
1.1 This practice covers guidelines for application of sprayed fiber and cementitious fire-resistive materials.
1.2 This practice is general in nature. It is not intended to cover all requirements for application.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 10 and 14.1.2.

2. Referenced Documents (purchase separately)
ASTM Standards
E119 Test Methods for Fire Tests of Building Construction and Materials
E605 Test Methods for Thickness and Density of Sprayed Fire-Resistive Material (SFRM) Applied to Structural Members
E631 Terminology of Building Constructions
E736 Test Method for Cohesion/Adhesion of Sprayed Fire-Resistive Materials Applied to Structural Members
E759 Test Method for Effect of Deflection on Sprayed Fire-Resistive Material Applied to Structural Members
E760 Test Method for Effect of Impact on Bonding of Sprayed Fire-Resistive Material Applied to Structural Members
E1368 Practice for Visual Inspection of Asbestos Abatement Projects
Index Terms
application; sprayed cementitious material; sprayed fire-resistive materials; sprayed mineral fiber material; Application; Installation--building materials/applications; Sprayed fire-resistive materials (SFRMs) ;


  詳情請(qǐng)咨詢
  防火資源網(wǎng)-阻燃防火測(cè)試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網(wǎng)"的所有作品,由<防火資源網(wǎng)>整理編輯,任何組織未經(jīng)<防火資源網(wǎng)>及其擁有者授權(quán),不得復(fù)制、轉(zhuǎn)載、摘編或利用其它方式應(yīng)用于任何商業(yè)行為。

 
 
[ 防火測(cè)試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關(guān)閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測(cè)試
推薦圖文
點(diǎn)擊排行
 
 
網(wǎng)站首頁(yè) | 廣告服務(wù) | 關(guān)于我們 | 聯(lián)系方式 | 服務(wù)協(xié)議 | 版權(quán)聲明 | 網(wǎng)站地圖 | 友情鏈接 | 網(wǎng)站留言 | 舊版本 | 閩ICP備09009213號(hào)
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號(hào):閩ICP備09009213號(hào)-1在線客服 點(diǎn)擊QQ交談/留言 點(diǎn)擊QQ交談/留言